T1 · Lookup

Fiber color chart — Free Online CalculatorFind the strand before you open the splice tray.

Look up the standard TIA-598 sequence for fiber, buffer tube, or ribbon positions 1–24. Search by number, color name, or abbreviation, then copy the exact identification for your work order.

Reference system

TIA-598

01—24

The first 12 base colors repeat with tracer markings for positions 13–24.

TIA-598 fiber color chart tool

TIA-598 FIELD REFERENCE

Fiber positions 1–24

Lookup controls

Identify a

Reference standard

TIA-598

Manufacturer legends planned

Fiber mode. Identify an individual coated fiber. Positions 13–24 repeat the twelve base colors with tracer markings.

Selected fiber

F-01

Blue

BL

Base color only

Identification
Fiber 1
Also called
No common alias
Use
Identify an individual coated fiber inside a buffer tube or cable core.
Reference
TIA-598 · Fiber mode

Reference sequence

Fiber positions 1–24

24 matches

On-screen swatches are visual references, not a calibration standard. Always confirm the manufacturer’s legend when identifying a live cable.

Keep the result moving

Fiber Color Chart — TIA-598, with a useful next step.

The fiber color chart is a field reference for identifying fiber positions before splicing, testing, labeling, or documenting a cable. TIA-598 uses a twelve-color sequence—blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, and aqua—to keep fiber order consistent across assemblies. Positions 13–24 repeat the base sequence with tracer markings, so the position number must be read together with the base color and tracer color. This tool lets technicians search by position, color name, or abbreviation and switch between individual fibers, buffer tubes, and ribbon fibers. The result includes the identification, color code, tracer information, and reference standard for a work order or test record. Color is a visual aid, not a substitute for the cable manufacturer’s legend. Housing, ink, lighting, aging, and regional naming can make slate look gray, rose look pink, or aqua look light blue. Confirm the physical marking against the product datasheet before opening a live closure or connecting test equipment. For production planning, use the exact cable construction and labeling convention supplied with the fiber optic cable, patch cord, pigtail, or ribbon assembly. When a project needs a custom sequence, this reference should be treated as a standards starting point rather than a final acceptance record.

Related reading and products

Explore the product options and technical background behind this result.

How to read the TIA-598 fiber color code

TIA-598 assigns a repeating sequence of twelve colors to identify fibers and sub-units. The sequence starts with blue and ends with aqua. For positions 13–24, the base colors repeat with a tracer; position 20 is the practical exception shown as black with a white tracer so the marking remains visible.

TIA-598 fiber color sequence positions 1 to 12
PositionBase colorAbbreviationCommon alias
1BlueBL
2OrangeOR
3GreenGR
4BrownBR
5SlateSLGray
6WhiteWH
7RedRD
8BlackBK
9YellowYL
10VioletVI
11RoseRSPink
12AquaAQLight Blue

Reference tool, not a substitute for the cable legend

Color naming can vary between regional standards and manufacturers, especially for slate/gray, rose/pink, and aqua/light blue. Before splicing or testing a live cable, compare the physical marking with the product documentation. For product selection, browse our fiber optic product range or ask a TTI Fiber engineer.